“I am continuously using a battery that I would otherwise have needed to replace.”
Company “C”, a conveyor manufacturer in Siheung, Gyeonggi-do Province, examined a battery because a forklift's usage time had drastically reduced. We discovered that the forklift had been used without refilling distilled water for five years.
Company “C” first restored the battery's usability by replenishing distilled water and operating an equalization charge. We measured the specific gravity of the electrolyte and installed REVIVER. After checking the battery state every month following installation, it was proven that the specific gravity of sulfuric acid, which was not within the usual range before installing REVIVER, moved within normal range. The battery, which seemed to require immediate replacement during the examination, has now been in operation for over a year.
02
Company O, Domestic food manufacturer
“Forklift battery management has been simplified thanks to REVIVER.“
Company “O”, based in Anyang, Gyeonggi-do, used forklifts for manufacturing, storing, and delivering convenience and frozen foods. Company “O” owned and operated approximately ten forklifts and found it difficult to manage the batteries by themselves. So, they chose to install REVIVER.
After three months of testing the efficiency of REVIVER on two of the ten forklifts, company “O” added REVIVER to the remaining forklifts. During the time that REVIVER was in use, all forklift batteries were monitored to see if any needed replacement or management. The ease of managing forklift batteries improved significantly after REVIVER was installed.
03
Company D, Domestic liquor distributor
“Cell-to-cell imbalance has been reduced and battery life has increased.“
Company “D”, based in Pohang, Gyeongsangbuk-do, an alcoholic beverage distributor, asked us to check their forklift’s battery. The forklift's usage duration was rapidly decreasing. Our on-site inspection revealed that one of 24 battery cells had a very low sulfuric acid specific gravity, indicating a faulty cell. We suggested replacement and installed REVIVER as a solution.
We rechecked the battery’s cells a month after installation. The cell imbalance had completely improved, the sulfuric acid specific gravity in all 24 cells had recovered, and battery usage duration increased.
04
Company S, Kia Motors' primary partner
“Output and usage time increased one week after installation."
Company “S” located in Gwangju, Jeollanam-do manufactures and supplies large automobile parts, such as automobile doors to Kia Motors, and operates a two-shift workplace. As a result, forklift operation was carried out under extreme conditions, with two sets of batteries being charged and used in alternation.
To address concerns regarding battery performance and usage time, Company “S” installed REVIVER on one of the two batteries. One week after installation, the forklift's output and usage time increased. After checking the results, Company A bought another REVIVER to install on their remaining forklift battery.